C-1100 Chem-Feed® Diaphragm Pumps
  • Double-ball inlet and outlet cartridge type ceramic check valves. Chemical resistant PVDF pump head, valve body and fitting, ceramic balls, Viton static seals and TFE/P ball seat o-rings. No metal springs are used.
  • 4 operating modes; manual on time per cycle adjustment, pulse input batching, 4-20mA on time per cycle adjustment, and 0-10v DC on time per cycle adjustment.
  • Stroke length can be manually adjusted to 5% of maximum.
  • Repeating interval on-time cycle timer is programmable in seconds, minutes, hours and days resulting in near infinite turndown ratio. Example: 5 seconds on per 10 day cycle.
  • On time per cycle can be controlled via 4-20mA signal. Note:
  • 20mA must equal maximum pump output.
  • Digital interval timer & 5-100% stroke adjustment results in a high frequency of small injections per minute.
  • Outputs to 15 GPH (56.8 LPH).
  • Output pressures to 150 PSI (10.3 bar).
  • PTFE coated EP diaphragm.
  • PVDF suction (foot) valve with Viton and TFE/P o-rings, ceramic check ball and removable polypropylene filter screen.
  • Includes 3/8″ OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting hardware.
  • Durable housing of chemical resistant Valox (PBT) thermoplastic.
C-1100V Variable Speed Pump
  • Double-ball inlet and outlet cartridge type ceramic check valves. Chemical resistant PVDF pump head, valve body and fitting, ceramic balls, Viton static seals and TFE/P ball seat o-rings. No metal springs are used.
  • Stroke length & speed adjustment for accurate small injections at a high rate per minute. 400:1 turndown ratio.
  • Outputs to 15 GPH (56.8 LPH).
  • Output pressures to 150 PSI (10.3 bar).
  • PVDF suction (foot) valve with Viton and TFE/P o-rings, ceramic check ball and removable polypropylene filter screen.
  • Includes 3/8″ OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting hardware.
  • Accepts 4-20mA, 0-10Vdc, and Pulse inputs for manual or external speed control.
  • Operator friendly digital touch pad.
  • –Easy to read LCD display
  • –Service and Alarm indicator icons.
  • –Display motor speed or input signal values.
  • –Prime mode for easy priming without changing programming.
  • Compatible with Blue-White’s output flow verification sensor system.
  • Durable housing of chemical resistant Valox (PBT) thermoplastic.
  • Diaphragm Metering Pumps Feed rates from:
  • up to 15 Gallons Per Hour up to 946 ml/min
  • Max working pressure 150 PSI.
C-1100F Variable Speed Pump
  • Double-ball inlet and outlet cartridge type ceramic check valves. Chemical resistant PVDF pump head, valve body and fittings, ceramic balls, Viton static seals and TFE/P ball seat o-rings. No metal springs are used.
  • 5-100% stroke adjustment results in a high frequency of small injections per minute.
  • Outputs to 947 ml/min (360 GPD).
  • Output pressures to 150 PSI.
  • PTFE coated EP diaphragm.
  • PVDF suction (foot) valve with Viton and TFE/P o-rings, ceramic check ball and removable polypropylene filter screen.
  • Includes 3/8″ OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting hardware.
  • Durable housing of chemical resistant Valox (PBT) thermoplastic.
C-1100E Fixed Speed Pump
  • Double-ball inlet and outlet cartridge type ceramic check valves. Chemical resistant PVDF pump head, valve body and fitting, ceramic balls, Viton static seals and TFE/P ball seat o-rings. No metal springs are used.
  • Stroke adjustment from 5-100% permits accurate small injections at a high rate per minute.
  • Adjustable 60 second repeating interval timer. 3 – 60 second adjustable on time per 60 second cycle.
  • Easy to use dial knob adjustment.
  • Outputs to 947 ml/min (360 GPD).
  • Output pressures to 150 PSI.
  • PTFE coated EP diaphragm.
  • PVDF suction (foot) valve with Viton and TFE/P o-rings, ceramic check ball and removable polypropylene filter screen.
  • Includes 3/8″ OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting hardware.
  • Compatible with Blue-White’s output flow verification sensor system.
  • Durable housing of chemical resistant Valox (PBT) thermoplastic.
C-1100C Fixed Speed Pump
  • Double-ball inlet and outlet cartridge type ceramic check valves. Chemical resistant PVDF pump head, valve body and fitting, ceramic balls, Viton static seals and TFE/P ball seat o-rings. No metal springs are used.
  • Stroke adjustment from 5-100% permits accurate small injections at a high rate per minute.
  • Adjustable 5 second repeating interval timer. 0.25 – 5.0 second adjustable on time per 5 second cycle.
  • Easy to use dial knob adjustment.
  • Outputs to 15 GPH (56.8 LPH).
  • Output pressures to 150 PSI (10.3 bar).
  • PTFE coated EP diaphragm.
  • PVDF suction (foot) valve with Viton and TFE/P o-rings, ceramic check ball and removable polypropylene filter screen.
  • Includes 3/8″ OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting hardware.
  • Compatible with Blue-White’s output flow verification sensor system.
  • Durable housing of chemical resistant Valox (PBT) thermoplastic.
C-1100A Fixed Speed Pump (time interval control - 60 second cycle timer)
  • Double-ball inlet and outlet cartridge type ceramic check valves. Chemical resistant PVDF pump head, valve body and fitting, ceramic balls, Viton static seals and TFE/P ball seat o-rings. No metal springs are used.
  • Stroke adjustment from 5-100% permits accurate small injections at a high rate per minute.
  • Adjustable 60 second repeating interval timer. 3 – 60 second adjustable on time per 60 second cycle.
  • Easy to use dial knob adjustment.
  • Outputs to 947 ml/min (360 GPD).
  • Output pressures to 150 PSI.
  • PTFE coated EP diaphragm.
  • PVDF suction (foot) valve with Viton and TFE/P o-rings, ceramic check ball and removable polypropylene filter screen.
  • Includes 3/8″ OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting hardware.
  • Compatible with Blue-White’s output flow verification sensor system.
  • Durable housing of chemical resistant Valox (PBT) thermoplastic.
C-1100X Fixed Speed Pump (continuous feed time / always on)
  • Double-ball inlet and outlet cartridge type ceramic check valves. Chemical resistant PVDF pump head, valve body and fittings, ceramic balls, Viton static seals and TFE/P ball seat o-rings. No metal springs are used.
  • 5-100% stroke adjustment results in a high frequency of small injections per minute.
  • Outputs to 947 ml/min (360 GPD).
  • Output pressures to 150 PSI.
  • PTFE coated EP diaphragm.
  • PVDF suction (foot) valve with Viton and TFE/P o-rings, ceramic check ball and removable polypropylene filter screen.
  • Includes 3/8″ OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting hardware.
  • Durable housing of chemical resistant Valox (PBT) thermoplastic.